NG16 Cetop7 Base Valve for Pilot Operated Directional Control Valve
DSHG-3C4-04-03
NG16 Pilot Operated Directional Control Valve
Cetop 7 – NG16 Mounting interface/Subplate Mounting
Base Valve Only. Requires an NG6 pilot valve on top.
Ports: P Port Blocked – A and B Open to T
Spring Centered 3 Position
Important:
Pilot: Valves are set up as Internal pilot, but can be converted to External Pilot.
Drain: Valves are set up as External drain, but can be converted to Internal drain.
Mounting Surface: CETOP7 / ISO 07-NFPAD07
Flowrate: 135-300Lpm / 35.7~79.3USgpm
Max Operating Pressure: 315Bar / 4500Psi
Min Required Pilot Pressure: 8Bar / 114Psi
Max Pilot Pressure: 250Bar / 3600Psi
Permissible Back Pressure T Ext. Drain: 210Bar / 300Psi
Permissible Back Pressure T Int. Drain: 160Bar / 2300PSI
Switching Frequency: 120 times/min
Operating Temp Range Recommended: -15°C ~ +70°C
Operating Velocity: 15 ~ 400cSt
Filtration: 25 Microns Absolute or Finer
Hydraulic Fluids: Use Hydraulic fluids equivalent to ISO VG32 or VG46
Includes below Socket Head Cap Screws:
2X M6x45Lg – Tightening Torque 12-15NM
and 4X M10x45Lg – Tightening Torque 5872NP
To add a NG6 3C4 Pilot Valve to this Base Valve, see the below options:
DSG-3C4-01 AC
DSG-3C4-01 DC
Other known codes: DSHG-3C4-04, DSHG-04-3C4, DSHG-3C4-04-30, DSHG-3C4-NO4
PLEASE NOTE THAT COURIER COST MAY NOT BE 100% ACCURATE ON HOSE ASSEMBLIES OR BULK, IT IS ADVISED TO REQUEST COURIER COST SEPERATE UPON ORDERING. YOU ARE WELCOME TO CALL OR EMAIL TO GET ACCURATE COSTING ON COURIER PRIOR TO ORDERING.
Items in stock may sometimes differ slightly from those in the pictures, but they are functionally the same.